ENGINEERED FOR WATER. BUILT FOR THE FIELD.
775.832.0495My Halogen Track an order Cloud login
Halogen Systems
descriptionTechnical Research

White Papers

Technical research, application guides, and engineering reports from Halogen Systems and industry partners.

Halogen Systems

The Domino Effect of an Analyzer Waste Stream

Evaluate the true installed cost of continuous analyzer discharge at wells and pump stations. Includes water-volume calculations, disposal infrastructure, installation options, and a value-engineering checklist.

By Halogen Systems Inc.

Value EngineeringWaste StreamCost SavingsWet-Tap
open_in_newRead Online
Halogen Systems

Distribution-Wide Water Quality Intelligence

A technical overview of continuous, spatially distributed sensing of disinfectant chemistry and pressure — and its integration with EPANET / EPANET-MSX hydraulic and water-quality models. Covers the measurement gap in distribution, network-wide nitrification prediction, contamination detection, NJ S2188 minimum-residual compliance, and containing boil-water advisories.

By Halogen Systems Inc.

DistributionMonochloramineEPANETNJ S2188Nitrification
open_in_newRead Online
Halogen Systems

See Your Whole Distribution System — A Brief for Utility Leaders

A plain-language brief for utility decision-makers on how a network of continuous, self-powered water-quality and pressure sensors protects water quality, meets new minimum-residual rules like NJ S2188, contains boil-water notices, and lowers operating cost.

By Halogen Systems Inc.

DistributionNJ S2188Smart WaterCost Savings
open_in_newRead Online
Halogen Systems

Chlorine Analyzers Waste 6.1 Billion Gallons of Non-Revenue Water

Traditional sensors waste 70,000–138,000 gallons of treated water per sensor per year. Across the U.S. this totals 6.1 billion gallons annually. The MP-5F eliminates this entirely with direct in-pipe installation.

By Halogen Systems Inc.

Water ConservationNon-Revenue WaterCost SavingsNSF-61
open_in_newRead Online
Halogen Systems

MP-5F: A New Standard in Accuracy

Calibrated once at pH 8.0, sensors in Halogen’s test stayed within ±4% (spec: ±5%) as pH varied from 6.5 to 8.5, temperature from 10–35°C, and conductivity from 156–10,000 µS. Limit of detection 30 ppb (0.03 ppm).

By Halogen Systems Inc.

AccuracyMP-5FpH CompensationTesting
open_in_newRead Online
Halogen Systems

Sensors Are the Missing Link for Legionella Control

Legionella causes more hospitalizations than carbon monoxide yet buildings rarely monitor water quality continuously. This paper explains why existing sensors fail in hot water systems and how the MP-HOT changes that.

By David J. Swiderski (HC Info) & Michael Silveri (Halogen Systems)

LegionellaHot WaterASHRAE 188Buildings
open_in_newRead Online
Halogen Systems

Monochloramine Measurement, Without Reagents

A continuous, reagent-free approach to measuring free chlorine and monochloramine on the same sensor — and the new control strategy it enables for chloraminating plants. Covers species-ambiguity problems with DPD Total, the nitrification cascade from ammonia-forward operation, and a chlorine-forward control method made possible by the MP-TOTAL.

By Michael Silveri, Founder, Halogen Systems Inc.

MonochloramineChloraminationMP-TOTALReagent-Free
open_in_newRead Online
Halogen Systems

Demand-Based Flushing with AMI & Water Quality Sensors

How the City of Gainesville, GA integrated Halogen MP5-A sensors (current model: MP-5F) with Sensus AMI infrastructure to enable condition-triggered automatic flushing. 99.875% sensor uptime over 6 months at 184 PSI.

By Halogen Systems Inc. & Sensus (Xylem)

AMI IntegrationDistributionFlushingSmart Water
open_in_newRead Online
Halogen Systems

ORP versus Amperometry for Chlorine Measurement

A detailed technical comparison of ORP and amperometric measurement methods for Total Residual Oxidant. Covers ORP electrode poisoning, ±30% concentration error, logarithmic response limitations, seawater baseline variability, and why amperometry is the correct choice for quantitative control.

By Halogen Systems Inc.

ORPAmperometrySensor TechnologyTRO
open_in_newRead Online
Halogen Systems

New Alternatives to Online DPD Instruments for TRO Measurement in BWMS

ACT-evaluated amperometric TRO sensor technology for ballast water management systems. Reagent-free, flow-independent, DNV Type Approved — with third-party precision data, cost comparisons, and field test results showing 1.2 years of maintenance-free operation.

By Halogen Systems Inc.

TROBWMSACT EvaluationMaritime
open_in_newRead Online

Looking for case studies or articles?

Browse our full library of technical documentation.

library_booksAll Resources