- Info CenterHalogen SensiCLĒNE™ The MP5™ was created with stable calibrations and low maintenance as priority requirements. To that end,...Real Talk about "Continuous Monitoring" Chlorine Analyzer claims Some manufacturers of online chlorine analyzers are making bold claims...
- Industries & ApplicationsMaritime & Aviation
Potable Water
Airport & AirPLane Monitoring
Inflow Source Monitoring
Tanker Monitoring
INDUSTRIALCommercial Buildings
Industrial Processing
Applications - ProductsHalogen SensiCLĒNE™ The MP5™ was created with stable calibrations and...Real Talk about "Continuous Monitoring" Chlorine Analyzer claims Some manufacturers...
- Contact
- Cloud
Halogen Amperometric Chlorine Sensors
The Halogen TRO Ballast Water Analyzer
Overview
A breakthrough for ballast water monitoring, The Halogen System TRO Multiple Parameter Sensor tests 5 parameters using a 3-electrode amperometric chlorine measurement. The sensor is unaffected by flow or pressure, is self-cleaning, and automatically compensates for pH. The TRO sensor utilizes Halogen’s patented RapidResponse ORP™ technology, a specialized implementation of ORP measurement that will report more consistent numbers thanks to a high resistance to poisoning.
The HSI sensor requires little to no maintenance, can be installed in a flow cell or directly in a pipe. Simple to install and inexpensive to operate, the Halogen TRO sensor is unlike any other ballast water analyzer on the market today.
Unique Features
- 5 Parameters in a single online near-time analyzer
- TRO
- pH
- Temperature
- Conductivity
- Rapid Response ORP™*
- Self-cleaning & low maintenance
- No membranes or electrolyte
- Factory calibrated, minimal drift
- Flexible deployment types
- System is equipped with 4 20mA and MODBUS RTU. Other communication protocols are available upon request.
- 24 VDC or 90 to 240 VAC operation
Benefits of the HSI TRO Sensor
Flow Independent Measurement
The sensor is unaffected by flow velocity changes from 0 to 4 m/s. An integrated pump that utilizes a long-lasting, brushless motor delivers a fixed velocity across the electrodes, creating flow independence in any installation. The high-velocity flow across the electrodes improves sensitivity and lowers the Signal to Noise Ratio.
Ease of Service
A Wet Tap installation method enables direct insertion into a distribution pipe. Sidestream, deployments are available. Whatever deployment, the highly integrated design reduces the electronics cost and size while increasing reliability.
SensiCLĒNE™ Patented Self-Cleaning Technology
A patented electrochemical cleaning method called SensiCLĒNE™ resists polarization and adsorption of organics. Cleaning beads continuously abrade the sensor. This keeps the electrode surfaces, including the pH sensor, free from buildup, scaling, and biofouling. Solid metal electrodes last the life of the system.
These features combine to enable very long intervals between calibrations.
Easy to Monitor
An optional local Display is available for viewing parameters, troubleshooting and calibration of up to 5 separate MP5™ units.
Models and Deployment Types
MP5™ H1 Wet Tap (H1WT)
The Wet Tap (or Hot Tap) housing can be deployed as a retractable direct pipe insertion for NSF-61 usage. No-leak retractor options are available.
MP5™ H1 Mid Flange (H1MF-p)
The mid-flange housing (H1MF-P) and the associated 2″ adapter sleeve and collar kit make for an easy sidestream NSF-61 PVC Tee deployment.
H1 Low FLANGE (H1LF-P)
The low-flange model (H1LF-P) can be used to replace existing control-board-mounted setups or used as an NSF-61 submerged in-tank analyzer.
Documents & Manuals for Ballast Water Analyzers
Installation Manual
Installation Manual for Halogen Chlorine Analyzer: E-SWN-P+ Standard Sensor
Installation Manual
Installation Manual for Halogen Chlorine Analyzer: E-SWN-PS (+) Standard Sensor
Installation Manual
Installation Manual for Halogen Chlorine Analyzer: E-SWN-PS+ Standard Sensor
Installation Manual
Installation Manual for Halogen Chlorine Analyzer: E-SWN-PS+ -A2 Standard Sensor
Installation Manual
Installation Manual for Halogen Chlorine Analyzer: E-SWN-PHT2 (+) Sensor
Installation Manual
Installation Manual for HSI Titanium Wet Tap solution including sensor probe, titanium ball valve, and remover system
Operations Manual
Operations Manual for Ballast Water Chlorine Analyzers:
- SWN-PSWN- P+
- SWN-PS, SWN-PS+
- EX-P-HT4
- EX-P-STD
- EX-P-STD2
- SWN-P-HT2
- SWN-P-HT2+
- SWN-HT2+
Operations Manual
Operations Manual for Ballast Water Chlorine Analyzers:
- SWN-P-HT2+
- SWN-P+
- EX-P-HT4
- EX-P-STD
- EX-P-STD2
Operations Manual
Operations Manual for Ballast Water Chlorine Analyzers using firmware 4.80 and prior:
- SWN- P+
- EX-P-HT4
- SWN-HT2+
Amperometric Chlorine Sensors With Patented Technology to Modernize Your Testing
Bare Electrode Sensor
Amperometric Sensors have many advantages over the older membrane and reagent technology. Halogen’s implementation of bare 3-electrode amperometric technology provides pH-stabilized measurements of Free Chlorine without introducing additional complexity to your workflow.
Self Cleaning
The old amperometric technology used by competitor sensors still requires a membrane and electrolyte to guard against sensor fouling. Such membranes are sensitive to flow and pressure spikes. Halogen’s patented SensiCLĒNE™ technology prevents fouling without introducing pressure or flow sensitivity.
Have Questions? Get Answers.
If the technologies and benefits listed above raise any questions, you may find the answer you’re looking for in the FAQ or Technologies pages.
Our contact page also allows you to reach out with a specific question and we’ll get back to you as quickly as possible.