Chi è l'HSI?

Started in a garage in a small town in Nevada, Halogen Systems, Inc. qualified for a Small Business Innovative Research Contract (SBIR) from the Office of Naval Research (ONR) via a program for the US Navy. Halogen developed a residual chlorine analyzer that met parameters most industry insiders felt were impossible. In 2021, Halogen began extending this proven technology into additional industries, starting with Drinking Water systems, both large and small. Halogen has been deployed in additional sectors such as offshore wind farms, environmental water recovery (EWR) systems such as rainwater collection, cooling towers, greywater systems, and industrial hot-water systems.

Nobody thought that an amperometric sensor would be durable enough to handle in-pipe pressures, much less going from 0 to 140 psi in under 4 minutes, in saltwater, in silty harbors without any drift for months, but they did it, and it’s amazing.”– BWMS Engineer

“In 40 years of Drinking Water plant experience, I have never seen anything as impressive as the MP5™. The flexibility, functionality, and stability are unmatched. Period.” – DW Systems Engineer

Halogen Systems, Inc. è impegnata a risolvere i problemi di monitoraggio dell'acqua con una tecnologia innovativa.

Monitoring residual chlorine in drinking water technology for decades required complicated flow-control piping, membranes, and reagents. That complexity created a standardized culture of constant maintenance because the residual chlorine analyzers were isolated from the main flow (sometimes hundreds of feet away), which may have caused measurements to be delayed by five minutes or more. 

Halogen’s amperometric chlorine analyzer technology allows a sensor to be inserted directly into a pipe. Durable and non-reactive, no flow control or waste drain is needed, and the sensor’s calibration remains constant under virtually any pressure or flow. Even a dry pipe won’t shake the calibration. 

With Halogen’s technology, the days of constant maintenance for chlorine sensors are over. The absence of membranes or reagents means that maintenance requirements have been significantly reduced, leading to substantial cost and time savings. This shift has been particularly beneficial for Ballast Water Management Systems (BWMS) manufacturers, and the Drinking Water industry is also enjoying the advantages of this residual chlorine analyzer, with NSF-61 Certification and approval for the EPA EPA Method 334.0 compliance reporting. 

Halogen’s technology has not only revolutionized ballast water monitoring but also demonstrated its adaptability to different industries. It has successfully addressed long-standing challenges in the Marine Ballast Water Management industry, and now, Halogen is leveraging this experience to solve mission-critical problems in industries like Drinking Water, Commercial Hot Water Systems, and Environmental Water Reclamation. Its simplicity, accuracy, and stability make it a versatile solution for a wide range of applications.

VANTAGGI PER L'AMBIENTE E ALTRO ANCORA

Trattamento dell'acqua di zavorra per le specie invasive

Le specie invasive (come le cozze zebrate) creano scompiglio negli ecosistemi. Molti di questi organismi sono portati dalle acque di zavorra delle navi da carico che attraversano gli oceani o i porti. Queste navi scaricano, a volte, milioni di litri d'acqua durante le operazioni. L'acqua non trattata può avere un impatto eccessivo sugli ecosistemi locali. Fortunatamente, oggi le navi sono tenute a sterilizzare l'acqua di zavorra e a eliminare le specie invasive prima di scaricarla, utilizzando un sistema di trattamento (BWTS). Molti BWTS utilizzano il sensore TRO per acqua di zavorra di Halogen Systems Inc. Halogen Systems Inc. per misurare il livello di ossidante per controllare il processo di trattamento. Il sensore TRO di Halogen garantisce anche che il livello di ossidante dell'acqua scaricata sia sicuro per il rilascio. La misurazione del cloro nell'acqua di zavorra è la più difficile di tutte le applicazioni a causa di biofouling, elevata durezza dell'acqua, alti livelli di sale e temperature estreme. 

La tecnologia di Halogen consente di inserire il sensore direttamente nel tubo dell'acqua di zavorra o nel flusso dell'acqua potabile. Resistente e non reattivo, non è necessario un controllo del flusso o uno scarico e la calibrazione del sensore rimane costante con qualsiasi pressione o flusso. Anche un tubo asciutto non altera la calibrazione. 

La tecnologia innovativa di Halogen ha affrontato efficacemente le sfide persistenti nel monitoraggio delle acque di zavorra, anche in circostanze operative difficili, offrendo una combinazione di semplicità, precisione e affidabilità. Oggi Halogen sfrutta le preziose conoscenze acquisite nell'esigente settore della gestione delle acque di zavorra marine per affrontare problemi cruciali in vari settori, come l'acqua potabile, le acque reflue, i sistemi commerciali di acqua calda e il recupero delle acque ambientali.

Municipal Drinking Water Online Chlorine Analyzer

It took us several years to generate a reliable sensor for such a harsh environment as seawater. Since we have successfully provided a sensor for the most strenuous application, developing similar sensor technology for drinking water treatment plants is comparatively easy.

Since this technology does not use membranes or reagents, maintenance requirements for residual chlorine analyzers can go from constant to minimal. Manufacturers of Ballast Water Management Systems (BWMS) and Marine regulators saw immediate benefits. Now, the Drinking Water industry is taking note, with both NSF-61 Certification and approval for EPA EPA Method 334.0 compliance reporting. 

The Halogen Sensor has been granted 11 patents worldwide and is the only online chlorine sensor with NSF61 certification. This allows it to be inserted directly into a drinking water pipe without a required waste stream. It can do this because it is the only sensor unaffected by fluctuating flow speed or pressure. The flow-generating technology also means that Halogen’s sensors work just as effectively when suspended or placed in a water tank. 

Standard Membrane and reagent residual chlorine sensors (such as the Hach CL17) require a waste stream of roughly 70,000 gallons of water per year to obtain their readings. Besides excessive water consumption, the cost of the treated water simply going to waste is, on average, $150 per year per sensor. Some utilities have over 100 analyzers operating with waste streams, resulting in a significant wasteful expense. The waste stream from such old-technology sensors cannot simply be discharged into the environment and requires additional chemical reagents, typically adding an average of $700 per year per analyzer plus labor. 

With NSF-61 Certification and no need for waste streams or reagents, Municipal drinking water utilities worldwide are already benefiting from using the residual chlorine analyzer.

Analisi e monitoraggio del cloro nel trattamento delle acque reflue

Gran parte delle acque reflue trattate viene "recuperata" o riciclata per altri usi, come l'irrigazione. Si tratta di applicazioni difficili per i sensori convenzionali che richiedono una ricalibrazione frequente. Ad esempio, in un impianto di trattamento delle acque reflue di Orlando, in Florida, i sensori attuali (una delle unità del nostro concorrente) devono essere calibrati tre volte al giorno (per ogni turno di lavoro) per ottenere letture accurate. Tuttavia, i sensori di Halogen Systems non richiedono la calibrazione per oltre un mese di funzionamento e leggono con precisione subito dopo l'installazione con le calibrazioni impostate in fabbrica. La calibrazione rimane poco frequente con i nostri sensori grazie al nostro sistema brevettato di autopulizia continua. Il nostro approccio ai sensori di cloro residuo mantiene la superficie di rilevamento libera da sostanze organiche e altre forme di accumulo.

Halogen Systems Inc. ha modificato il suo sensore per le acque reflue e ha spedito il primo sensore nel maggio del 2021. Diversi impianti di trattamento delle acque reflue in Florida hanno richiesto l'approvazione del Dipartimento di Protezione Ambientale della Florida per l'utilizzo del nostro sensore per la rendicontazione della conformità. Orlando, Florida, è la prima città ad aver ottenuto l'approvazione del DEP. Altri comuni riceveranno presto le stesse approvazioni dal DEP della Florida e a quel punto le apparecchiature di Halogen Systems Inc. sostituiranno la loro vecchia tecnologia. "Questo consente un controllo molto più rigoroso del processo dell'impianto, con meno manodopera, più affidabilità, maggiore precisione e minore utilizzo di prodotti chimici", afferma Jason Erskine di HASK, Inc.

Poiché questa tecnologia non utilizza membrane o reagenti, i requisiti di manutenzione per i sensori di cloro possono passare da costanti a minimi. I produttori di sistemi di gestione dell'acqua di zavorra (BWMS) e le autorità di regolamentazione marittima hanno riscontrato vantaggi immediati. Ora anche l'industria dell'acqua potabile sta prendendo nota, con la certificazione NSF-61 e l'approvazione per la comunicazione di conformità al metodo 334.0 dell'EPA. 

Il sensore alogeno ha ottenuto 11 brevetti in tutto il mondo ed è l'unico sensore di cloro online con certificazione di livello NSF61. Ciò consente di inserirlo direttamente nelle tubature dell'acqua potabile senza che sia necessario un flusso di scarico. Questo perché è l'unico sensore che non è influenzato dalle fluttuazioni di velocità o pressione del flusso. La tecnologia di generazione del flusso significa anche che i sensori Halogen funzionano altrettanto efficacemente quando sono sospesi o semplicemente collocati in un serbatoio d'acqua. 

Sensori di cloro residuo a membrana e a reagente standard (come Hach CL17) richiedono un flusso di rifiuti di circa 69.000 galloni di acqua all'anno per ottenere le loro letture. Oltre al consumo eccessivo di acqua, il costo dell'acqua trattata che va semplicemente sprecata è, in media, di 150 dollari all'anno per sensore. Alcune aziende hanno più di 100 analizzatori in funzione con flussi di scarto, il che comporta un notevole spreco di risorse. Il flusso di scarti di questi sensori di vecchia tecnologia non può essere semplicemente Il flusso di rifiuti di questi sensori di vecchia tecnologia non può essere semplicemente scaricato nell'ambiente e quindi richiede l'uso di reagenti chimici aggiuntivi, che in genere aggiungono una media di 700 dollari all'anno per analizzatore più la manodopera.

Grazie alla certificazione NSF61 e all'assenza di flussi di rifiuti o reagenti, le aziende municipali di acqua potabile in Florida, California e Nevada stanno già valutando l'impiego del sensore.

Online Chlorine Analyzer Designed for Simplicity and Flexibility

Whether designing a complete Ballast Water Management System (BWMS) or Municipal Drinking Water facility, architects, engineers, and operators appreciate the confidence they gain from Halogen’s remarkable calibration stability as much as they enjoy the flexible installation types and near-zero maintenance. Contact Halogen today to learn more about designing your system for flexibility and simplicity.