- Centro de informaciónHalógeno SensiCLĒNE™ El MP5™ se creó con las calibraciones estables y el bajo mantenimiento como requisitos prioritarios. Para ello,...Real Talk about "Continuous Monitoring" Chlorine Analyzer claims Some manufacturers of online chlorine analyzers are making bold claims...
- Industrias y aplicacionesMarítimo y aviación
Agua potable
Control de aeropuertos y aviones
Control de las fuentes de entrada
Control de camiones cisterna
INDUSTRIALTransformación industrial
- ProductosHalógeno SensiCLĒNE™ El MP5™ fue creado con calibraciones estables y...Real Talk about "Continuous Monitoring" Chlorine Analyzer claims Algunos fabricantes...
- Contacte con
MP5™ Online Analyzer forEnd-of-Line Monitoring
Reduce Non-Revenue Water Waste with an MP5™
Halogen’s MP5™ chlorine analyzer is a good foundation for water aging flushing strategies.
Whether a public water system (PWS) uses flushing as part of a regular maintenance schedule or in response to low disinfectant residual, water flushing is an important tool in maintaining a healthy water grid. However, as water waste becomes a more pressing issue, PWS operators must be judicious in the use of the technique.
Many water systems operators are interested in automating the process and there are on-market solutions that can flush at predetermined times and for predetermined amounts of time. Even better are solutions that are based on water-aging parameters, like residual free chlorine, pH, and ORP. The Halogen MP5™ chlorine sensor measures those parameters along with temperature and conductivity in a single online, near-time unit.
The MP5™ is approved for NSF-61 use in drinking water pipes with no required waste drain and is well-regarded for stable calibration and low maintenance. These and other qualities make the MP5™ uniquely suited for dead-end monitoring and flushing solutions.
Solve end-of-Line Problems with the MP5™ Online Chlorine Sensor
5 Parameters in One Unit
The NSF-61 certified, Halogen MP5™ measures 5 testing parameters in near-time using one online unit without losing a drop of treated water. Operators can assess free chlorine, pH, temperature, conductivity, and oxidation-reduction potential (ORP) in near-time in the pipe with no waste stream required.
Flexible deployment options
The MP5™ makes things simple. There are no reagents or membranes to stock, manage, or replace. Our NSF-61 certification means no flow-control plumbing and no waste stream to mitigate. The MP5™ is unaffected by flow or pressure, and the only chlorine analyzer that can be inserted as a wet tap in a drinking water pipe.
Unaffected by Pressure or Flow
The MP5™ adapts to nearly any flow or pressure. Even a dry pipe won’t ruin the calibration. It can be installed directly in a pipe, located side-stream, suspended in a trough, or simply dropped in a tank. Whatever the deployment type or parameters, the MP5™ is unique in accuracy, reliability, and stability.
Sensores amperométricos con tecnología patentada para modernizar sus pruebas
Bare Electrode Sensor
Halogen’s amperometric sensors have many advantages over DPD-style membrane and reagent technology. Halogen’s implementation of bare 3-electrode amperometric technology provides pH-stabilized precise measurements of Free Chlorine without introducing additional complexity to your workflow.
Self Cleaning
The old amperometric technology used by competitor sensors still requires a membrane and electrolyte to guard against sensor fouling. Such membranes are sensitive to flow and pressure spikes. Halogen’s patented SensiCLĒNE™ technology prevents fouling without introducing pressure or flow sensitivity.
MP5™ SOLUTIONS AND KITS
Kit with flow-cell deployment (MKIT) and display controller along with a wall mounting plate, provides a drop-in upfit sensor replacement.
Battery power and remote telemetry for an MP5™ deployment. Use for outer grid monitoring, dead-ends, or other remote implementations.
Leverage the dependability and low maintenance of the MP5™ for remote tank monitoring with battery power and remote telemetry.
Retractable remover kit for MP5™ wet-tap analyzer (H1WT-P) in water pipes allows for maintenance without interrupting flows.
This deployment uses a water-proofed low-flange MP5™ (H1LF-P), a sourced boom and harness, or can simply be placed in a tank or trough.
Combine a mid-flange MP5™ (H1MF-P) with an adapter sleeve—in PVC or Stainless steel—sized for deployments in a 2″ PVC tee.
Fits low-flange MP5™ (H1LF-P) and adapts for side stream and control board usage based on which flow cell type is ordered.
Both 24V DC (DC20-L) and 120-240V AC (DC20-H) versions feature (4) 4-20 mA analog outputs, and an M-12 Connector, 3 relays, SD card.
¿Tiene preguntas? Obtenga respuestas.
If the technologies and benefits listed above raise any questions, you may find the answer you’re looking for in the FAQ or Technologies pages.
Our contact page also allows you to reach out with a specific question and we’ll get back to you as quickly as possible.