Ballast Water TRO Sensor

Accurate at Virtually Any Pressure Or Any Flow

The patented technology in the Halogen® TRO Amperometric Chlorine Sensor allows for Direct Pipe Installations (also called a “Wet Tap installation’) which means there is no need for complicated additional piping for flow-control or waste lines. It is unaffected by flow changes ranging from 0 to 4 meters per second, and tolerates pressures from -.7 bar (-10.15 psi)  to 10 bar (147 psi). The TRO sensor contains the only pH sensor on the market that can survive both high and negative pressures within a ballast pipe.

Measure Five Parameters in One Online TRO Sensor

모니터링을 간소화하는 기술

The TRO Sensor features the following tech: 
SensiCLĒNE™ beads continuously clean the electrodes. Rapid Response ORP™ won’t get poisoned or damaged if allowed to dry out. The HiResTRO™ impeller enables Direct Pipe Insertion. HaloSAL™ provides accurate readings in any salinity. DryGLAS™ protects the pH sensor if the ballast pipe is emptied.

유량 및 압력에 영향을 받지 않는 할로겐 MP5 염소 센서 NSF-61

안정적인 캘리브레이션 = 추측이 필요 없음

수개월 동안 지속되는 캘리브레이션과 밸러스트 이송 파이프에 직접 설치할 수 있는 기능을 갖춘 Halogen® TRO™는 10분 후 복잡한 유량 제어 라인 끝에 있는 샘플링 보드의 구식 센서가 아닌 정확한 순간에 실제 파이프의 물 속 상태를 명확하게 파악할 수 있습니다.

하나의 온라인 장치에 5개의 매개변수

할로겐 디스플레이 장치(HDU)는 센서에서 수백 피트 떨어진 곳에 배치할 수 있습니다. HDU는 PLC 또는 다른 전원을 통해 전원이 공급되며 데이터가 화면에 실시간으로 표시되는 동안 디스플레이는 Modbus RTU 프로토콜 또는 4-20mA 아날로그 신호를 사용하여 이러한 매개 변수를 SCADA 시스템과 통신할 수도 있습니다.

MP5™ ROI Calc: 낮은 운영 비용 + 최소한의 유지보수 + 물 낭비 제로

항만 내 선박평형수 투기 - BWMS - 염소 모니터링

예산을 낭비하는 구식 기술 센서

DPD-based systems require a host of flow-control and waste-return lines that must be designed, installed, and maintained. In addition to replacing membranes and reagent, calibrations are a full-time job for maintenance teams. The Halogen® TRO Sensor needs no flow control, no membrane, no reagent, and requires very little maintenance. 

(더 많은 혜택)

할로겐 BWMS 인증: 미국 해안경비대, DNV-GL, IECEx, 한국선급

할로겐® 인증 목록

Recognized by the US Coast Guard, The Korean Register, and the IMO, the Halogen® TRO™ sensor is allowed for direct replacement of a DPD sensor with no required recertification. Halogen also has IECEx certification for use in explosive environments. Using a Halogen TRO Sensor instead of a DPD in a BWMS  system reduces complexity and maintenance while providing flexibility and accuracy. (See More)

선박평형수 TRO 센서 브로셔

유속, 염도 또는 탁도에 관계없이 모든 물에서 TRO 측정

유지보수 비용을 낮추면서 정확성과 단순성을 더하세요.

BWMS 시스템을 처음부터 구축하든 기존 시스템을 업그레이드 및 개조하든, 엔지니어는 센서의 한계가 아닌 작업자의 요구 사항을 중심으로 설계할 수 있을 때 얻을 수 있는 유연성을 높이 평가합니다. 할로겐 TRO가 모니터링 프로세스에 어떤 이점을 제공하는지 확인해 보세요.

할로겐 BWMS TRO 염소 센서

DPD 센서의 이상적인 대안

BWMS 설계자와 운영자는 이제 DPD 시스템에 대한 이 매력적인 대안을 통해 운영 비용을 절감하고 유지보수를 줄일 수 있습니다.

시간과 비용을 절약하는 할로겐™ TRO™

해상 운송 산업을 괴롭히는 환경 영향 문제를 해결하기 위해 개발된 특허 기술을 갖춘 할로겐의 TRO 센서는 멤브레인 및 시약 비용을 예산에서 제거합니다. 하지만 이는 시작에 불과합니다. 안정적인 캘리브레이션과 최소한의 유지보수 덕분에 한 달에 수백 시간을 다른 용도로 사용할 수 있습니다.