Ballast Water TRO Sensor

Accurate at Virtually Any Pressure Or Any Flow
The patented technology in the Halogen® TRO Amperometric Chlorine Sensor allows for Direct Pipe Installations (also called a “Wet Tap installation’) which means there is no need for complicated additional piping for flow-control or waste lines. It is unaffected by flow changes ranging from 0 to 4 meters per second, and tolerates pressures from -.7 bar (-10.15 psi) to 10 bar (147 psi). The TRO sensor contains the only pH sensor on the market that can survive both high and negative pressures within a ballast pipe.
Measure Five Parameters in One Online TRO Sensor

简化监测的技术
The TRO Sensor features the following tech:
SensiCLĒNE™ beads continuously clean the electrodes. Rapid Response ORP™ won’t get poisoned or damaged if allowed to dry out. The HiResTRO™ impeller enables Direct Pipe Insertion. HaloSAL™ provides accurate readings in any salinity. DryGLAS™ protects the pH sensor if the ballast pipe is emptied.

稳定的校准=没有猜测
Halogen® TRO™可持续校准数月,并能直接安装在压载物输送管道中,它能清楚地了解水中的情况--在实际管道中的确切时刻,而不是在10分钟后通过复杂的流量控制管道末端的采样板上的旧技术传感器。

1个在线单元中的5个参数
卤素显示单元(HDU)可以放置在距离传感器数百英尺的地方。HDU通过PLC或其他电源供电,在屏幕上实时显示数据的同时,显示器还可以使用Modbus RTU协议或4-20ma模拟信号将这些参数传达给SCADA系统。
MP5™投资回报率计算:更低的运营成本+最少的维护+零水浪费

旧技术传感器耗尽预算
DPD-based systems require a host of flow-control and waste-return lines that must be designed, installed, and maintained. In addition to replacing membranes and reagent, calibrations are a full-time job for maintenance teams. The Halogen® TRO Sensor needs no flow control, no membrane, no reagent, and requires very little maintenance.

卤素®认证列表
Recognized by the US Coast Guard, The Korean Register, and the IMO, the Halogen® TRO™ sensor is allowed for direct replacement of a DPD sensor with no required recertification. Halogen also has IECEx certification for use in explosive environments. Using a Halogen TRO Sensor instead of a DPD in a BWMS system reduces complexity and maintenance while providing flexibility and accuracy. (See More)

压载水TRO传感器手册
在任何水体中测量TRO,不受流速、盐度或浊度影响

在降低维护成本的同时增加准确性和简单性
无论是从头开始建立BWMS系统,还是对现有系统进行升级和改造,当他们能够围绕操作人员的要求而不是围绕传感器的限制进行设计时,工程师们都会欣赏他们获得的灵活性。看看卤素TRO能为监测过程做些什么。

替代DPD传感器的理想选择
BWMS的设计者和操作者现在可以通过这种有吸引力的DPD系统的替代方案来降低运营成本和减少维护。
Halogen™ TRO™节省时间和金钱
凭借为解决困扰海运业的环境影响问题而创造的专利技术,Halogen的TRO传感器从预算中剔除了膜和试剂的成本。但这仅仅是个开始。由于稳定的校准和最低限度的维护,每月有数百个工时可以被重新利用。