MP-Mono™ Amperometric Chlorine Sensor

MP-Mono™: No Interference Monochloramine Readings

Municipal Drinking Water plants have been frustrated by the difficulty of accurately reading the monochloramine residual in their treated water for decades. Staying on the right side of the chlorine breakpoint curve has always been a delicate balance… until now

The MP-Mono™ accurately measures True Free Chlorine without interference from monochloramine and monochloramine without interference from dichloramine and trichloramine for precise control over the chloramination processes. Certified for NSF-61 installations, Halogen’s MP-Mono™, like the MP5-A™ Free Chlorine sensor, has a built-in impeller that generates a consistent flow across the diodes, capturing accurate and consistent readings. This same impeller excites cleaning beads in the sensor’s tip, allowing the patented cleaning system to clean the sensor surface. Because this sensor is flow-independent, self-cleaning, and does not need any waste stream, it can be installed virtually anywhere: inserted directly into a drinking water pipe, suspended in a trough, or dropped into a tank.

Measures Monochloramine & Free Chlorine All in One Chlorine Analyzer

Monochlormaine Analyzer at its best

The NSF-61 certified Halogen MP-Mono™ analyzer measures monochloramine and free chlorine in under two minutes using one online unit without wasting one drop of treated water. Operators can know where their monochloramine, free chlorine, pH, temperature, conductivity, and even control chemical feed with the D-20 Controller.

Sensor de cloro halógeno MP5 NSF-61 No se ve afectado por el caudal ni la presión

No se ve afectado por el caudal o la presión

The MP-Mono™ adapts to nearly any flow or pressure. Even a dry pipe won’t ruin the calibration. It can be installed directly in a pipe, located side-stream, suspended in a trough, or dropped in a tank. Whatever the deployment type or parameters, the MP-Mono™ is unique in accuracy, reliability, and stability.

Simplifique el flujo de trabajo

The MP-Mono™ makes things simple. Our NSF-61  certification means no flow-control plumbing and no waste stream to mitigate. There are no reagents or membranes to stock, manage, or replace. Instead, you’ll replace the cap, cleaning beads, and impeller blade once per year in 10 minutes without affecting its calibration.

The MP-Mono™ ROI Calc: Lower Operating Cost + Minimal Maintenance + Zero Water Waste

Los sensores de tecnología antigua desperdician agua tratada

¿Cuánta agua pierde?

An old-tech monochloramine sensor combined with a free-chlorine sensor requires around 138,000 gallons of flow per year to capture its readings. In areas subject to water restrictions, that is a lot of waste, but even in areas where water is plentiful, the treatment costs and maintenance headaches can all be avoided with the MP-Mono™.

The MP-Mono™ Makes Remote Tanks Easy

Installed directly in-pipe and unaffected by flow and pressure —even a dry pipe won’t throw off the calibration— the MP-Mono™ is a dream for operators with remote tanks. Combined with our battery-powered cellular reporting solution for the ultimate remote tank sensor solution.

MP-Mono™ Data Sheet

Sensores amperométricos con tecnología patentada para modernizar sus pruebas

Añada precisión y sencillez a la vez que reduce sus costes de mantenimiento

Los operarios de la planta saben exactamente cuánto dinero se gasta en membranas, reactivos y electrolitos. Lo que no está tan claro es cuánto tiempo dedica el equipo al mantenimiento y las calibraciones posteriores de los sensores de tecnología antigua. Esas horas de trabajo se acumulan rápidamente. En cambio, el MP5™ viene calibrado de fábrica y se estabiliza a los 5 minutos de su instalación. No sólo no hay membranas, reactivos o electrolitos, no hay mantenimiento mensual. Las plantas han visto calibraciones que duran muchos meses. Este tipo de simplicidad va directamente a la cuenta de resultados.

Online Chlorine Analyzer Report - Orange County Florida (OCFL)

Resultados del programa piloto del Condado de Orange, Florida

The operators and staff in this program were pleasantly surprised at just how little maintenance has been needed. “Sensor calibration is performed initially and has not been required in over six months…manpower savings are … an estimated savings of 2,080 man-hours per year for five sensors.” <read more>

Technology forged in the harshest environments. Now ready for yours.​

With patented tech created to solve the environmental impact issues dogging the maritime shipping industry, Halogen has created a solution that solves problems many wastewater plant operators had written off as “the way things are.” The Halogen MP-Mono™ and MP5-A™ are designed to let those same operators work within a new paradigm.